Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber
The European Physical Journal C SpringerOpen 85:11 (2025) 1334
Abstract:
Abstract The DarkSide-20k dark matter direct detection experiment will employ a $${21}\,\hbox {m}^{2}$$ 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles , each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. $$16$$ 16 Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide programme
ArXiv 2511.13629 (2025)
Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al2O3 crystal in CRESST-III
Physical Review D 112:10 (2025) 102008
Abstract:
The current generation of cryogenic solid state detectors used in direct dark matter and CEνNS searches typically reach energy thresholds of O(10) eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing monoenergetic nuclear recoils at low energies ∼100 eV–1 keV. In this work we report on the observation of a peak at (1113.6-6.5+6.5) eV in the data of an Al2O3 crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this monoenergetic peak to the radiative capture of thermal neutrons on Al27 and the subsequent deexcitation via single γ emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al2O3 detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
(2025)
The XLZD Design Book: towards the next-generation liquid xenon observatory for dark matter and neutrino physics
The European Physical Journal C SpringerOpen 85:10 (2025) 1192