Comparing the contrast performance of two IFU technologies for exoplanet direct imaging with ELT-PCS
Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation VII SPIE 14154 (2026)
Abstract:
A key science goal for the Planetary Camera and Spectrograph (ELT-PCS) instrument is to image rocky exoplanets in reflected light around nearby M- and K-dwarfs. These observations will require a contrast of 10−9 at 100 mas angular separation, and 10−8 at 10 mas. To achieve such an extreme performance, every instrument design choice must be carefully evaluated. For ELT-PCS’s science instruments, perhaps the most critical design choice is which integral field unit (IFU) technology to use. To this end, we have developed a modular, lab-based integral field spectrograph test bench with which to compare the performance of two popular IFU technologies: image slicers and lenslet arrays. The test bench implements a Lyot coronagraph and a spatial light modulator to simulate a high-contrast imaging system, which feeds each IFU with a diffraction-limited PSF image. Each IFU is coupled to the spectrograph, which achieves R≈3000 with the image slicer and R≈100 with the lenslet array. The calibration and data reduction for each IFU design are described and the initial results of a contrast comparison are presented. The lenslet array achieves a deeper contrast at angular separations of less than 6λ/D. The image slicer, however, gains more at small separations from applying spectral deconvolution, with a 3.4× greater gain at 4λ/D. Spectral deconvolution further yields a contrast curve close to the detector noise floor. Further work will focus on carrying out a fully-controlled characterisation of the lenslet array IFU and a more comprehensive study into the effects of adaptive optics residuals on the contrast.An integral field unit for the planetary camera and spectrograph (ELT-PCS): comparing lenslet and image slicer-based IFUs
Proceedings of SPIE--the International Society for Optical Engineering SPIE, the international society for optics and photonics 13100 (2024) 131001o-131001o-8
HARMONI at ELT: characterizing spatial variations in transmission efficiency of volume phase holographic diffraction gratings
Proceedings of SPIE--the International Society for Optical Engineering SPIE, the international society for optics and photonics 13100 (2024) 131001t-131001t-17
HARMONI at ELT: chromatic dependence of wavefront error performance in volume phase holographic diffraction gratings
Proceedings of SPIE--the International Society for Optical Engineering SPIE, the international society for optics and photonics 13100 (2024) 131005k-131005k-9
HARMONI-ELT instrument integral field unit test tools development
Proceedings of SPIE--the International Society for Optical Engineering SPIE, the international society for optics and photonics 13100 (2024) 131004l-131004l-13