The Level-3 trigger at the CDF experiment at Tevatron Run II

IEEE Trans. Nucl. Sci. 52 (2005) 1212-1216

Authors:

YS Chung, others

The mice focusing solenoids and their cooling system

(2005) 585-588

Authors:

MA Green, G Barr, W Lau, RS Senanayake, SQ Yang

Abstract:

This report describes the focusing solenoid for the proposed Muon Ionization Cooling Experiment (MICE) [1]. The focusing solenoid consists of a pair of superconducting solenoids that are on a common bobbin. The two coils, which have separate leads, may be operated in the same polarity or at opposite polarity. This report discusses the superconducting magnet design and the cryostat design for the MICE focusing module. Also discussed is how this superconducting magnet can be. integrated with a pair of small 4.2 K coolers.

Measurement of Ke30 form factors

Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics 604:1-2 (2004) 1-10

Authors:

A Lai, D Marras, A Bevan, RS Dosanjh, TJ Gershon, B Hay, GE Kalmus, C Lazzeroni, DJ Munday, E Olaiya, MA Parker, TO White, SA Wotton, G Barr, G Bocquet, A Ceccucci, T Cuhadar-Dönszelmann, D Cundy, G D'Agostini, N Doble, V Falaleev, L Gatignon, A Gonidec, B Gorini, G Govi, P Grafström, W Kubischta, A Lacourt, A Norton, S Palestini, B Panzer-Steindel, H Taureg, M Velasco, H Wahl, C Cheshkov, P Hristov, V Kekelidze, L Litov, D Madigojine, N Molokanova, Y Potrebenikov, S Stoynev, A Zinchenko, I Knowles, V Martin, R Sacco, A Walker, M Contalbrigo, P Dalpiaz, J Duclos, PL Frabetti, A Gianoli, M Martini, F Petrucci, M Savrié, A Bizzeti, M Calvetti, G Collazuol, G Graziani, E Iacopini, M Lenti, F Martelli, M Veltri, HG Becker, K Eppard, M Eppard, H Fox, A Kalter, K Kleinknecht, U Koch, L Köpke, P Lopes da Silva, P Marouelli, I Pellmann, A Peters, B Renk, SA Schmidt, V Schönharting, Y Schué, R Wanke, A Winhart, M Wittgen, JC Chollet, L Fayard, L Iconomidou-Fayard, J Ocariz, G Unal, I Wingerter-Seez, G Anzivino, P Cenci, E Imbergamo, P Lubrano, A Mestvirishvili, A Nappi, M Pepe, M Piccini, L Bertanza, R Carosi, R Casali, C Cerri

Abstract:

The semileptonic decay of the neutral K meson, KL0→π± e∓ν (Ke3), was used to study the strangeness-changing weak interaction of hadrons. A sample of 5.6 million reconstructed events recorded by the NA48 experiment was used to measure the Dalitz plot density. Admitting all possible Lorentz-covariant couplings, the form factors for vector (f+(q2)), scalar (fS) and tensor (fT) interactions were measured. The linear slope of the vector form factor λ+=0.0284±0.0007±0.0013 and values for the ratios |fS/f+(0)|=0.015-0.010+0.007±0.012 and |fT/f+(0)|=0.05-0.04+0. 03±0.03 were obtained. The values for fS and fT are consistent with zero. Assuming only vector-axial-vector couplings, λ+=0.0288±0. 0004±0.0011 and a good fit consistent with pure V-A couplings were obtained. Alternatively, a fit to a dipole form factor yields a pole mass of M=859±18 MeV, consistent with the K*(892) mass. © 2004 Elsevier B.V. All rights reserved.

Measuring Charged-Current Muon Neutrino Interactions in MiniBooNE

(2004)

The level-3 trigger at the CDF experiment at tevatron run II

IEEE Nuclear Science Symposium Conference Record 2 (2004) 1067-1071

Authors:

YS Chung, G De Lentdecker, S Demers, BY Han, B Kilminster, J Lee, K McFarland, A Vaiciulis, F Azfar, T Huffman, T Akimoto, H Kobayashi, H Matsunaga, M Shimojima, K Tollefson, D Torretta, D Waters

Abstract:

We describe the filtering and analysis software running in the CDF Run II Level-3 trigger as well as the client and event driven data hub system. These systems constitute critical components of the data acquisition system of the CDF detector. The Level-3 trigger is responsible for reconstructing the events and forming the final trigger decision. The Consumer-Server Logger (CSL) system receives the accepted physics events from multiple connections and writes them to disk in multiple streams while distributing them to online analysis programs (consumers). Since 2001 the system has been running successfully at high throughput rates: the Level-3 trigger reduces the event rate from 350 Hz to about 100 Hz with an average event size of 150 kB while the CSL is able to process up to 22 MB/s of constant event logging. We describe these systems in detail and report on their current performance. We briefly outline upgrade plans for the remainder of Tevatron Run II. © 2004 IEEE.