Large Synoptic Survey Telescope White Paper; The Case for Matching U-band on Deep Drilling Fields

Authors:

BW Holwerda, A Baker, S Blyth, S Kannappan, D Obreschkow, S Ravindranath, E Elson, M Vaccari, S Crawford, M Bershady, N Hathi, N Maddox, R Taylor, MATTHEW Jarvis, J Bridge

Abstract:

U-band observations with the LSST have yet to be fully optimized in cadence. The straw man survey design is a simple coverage of the medium-deep-fast survey. Here we argue that deep coverage of the four deep drilling fields (XMM-LSS, ECDFS, ELAIS-S1 and COSMOS) has a much higher scientific return, given that these are also the target of the Southern Hemisphere's Square Kilometer Array Pathfinder, the MeerKAT specifically, deep radio observations.

Measurement of the B meson and b quark cross-sections in $p\barp$ collisions at $\sqrts=$ 1.8-TeV using the exclusive decays $B^+ \to J/ψ K^+$ and $B^0 \to J/ψ K^*0$

16th International Symposium on Lepton and Photon Interactions

Authors:

F Abe, others

Medipix3 Demonstration and understanding of near ideal detector performance for 60 & 80 keV electrons

Authors:

JA Mir, R Clough, R MacInnes, C Gough, R Plackett, IAN Shipsey, H Sawada, I MacLaren, R Ballabriga, D Maneuski, V O'Shea, D McGrouther, ANGUS Kirkland

Abstract:

In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize either the MTF or DQE, obtaining values near to, or even exceeding, those for an ideal detector. We have demonstrated that the Medipix3 charge summing mode (CSM) can deliver simultaneous, near ideal values of both MTF and DQE. To understand direct detection performance further we have characterized the detector response to single electron events, building an empirical model which can predict detector MTF and DQE performance based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance, recording a fully exposed electron diffraction pattern at 24-bit depth and images in SPM and CSM modes. Taken together our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous and alternative architecture for direct electron imaging

Modelling baryonic feedback for survey cosmology

Authors:

NE Chisari, AJ Mead, S Joudaki, P Ferreira, A Schneider, J Mohr, T Tröster, D Alonso, IG McCarthy, S Martin-Alvarez, JULIEN Devriendt, A Slyz, MPV Daalen

Abstract:

Observational cosmology in the next decade will rely on probes of the distribution of matter in the redshift range between $0

Monte Carlo simulations of B(d)0 —\ensuremath> pi+ pi- from p p interactions at s**1/2 = 40-TeV

Authors:

OR Long, NS Lockyer, PT Keener, F Azfar, KT McDonald, JG Heinrich, LA Roberts