Progress Report on the Large-Scale Polarization Explorer

JOURNAL OF LOW TEMPERATURE PHYSICS Springer Science and Business Media LLC 200:5-6 (2020) 374-383

Authors:

L Lamagna, G Addamo, Par Ade, C Baccigalupi, Am Baldini, Pm Battaglia, E Battistelli, A Bau, M Bersanelli, M Biasotti, C Boragno, A Boscaleri, B Caccianiga, S Caprioli, F Cavaliere, F Cei, Ka Cleary, F Columbro, G Coppi, A Coppolecchia, D Corsini, F Cuttaia, G D'Alessandro, P de Bernardis, G De Gasperis, M De Petris, F Del Torto, V Fafone, Z Farooqui, F Farsian, F Fontanelli, C Franceschet, Tc Gaier, F Gatti, R Genova-Santos, M Gervasi, T Ghigna, M Grassi, D Grosso, F Incardona, M Jones, P Kangaslahti, N Krachmalnicoff, R Mainini, D Maino, S Mandelli, M Maris, S Masi, S Matarrese, A May

Abstract:

© 2020, Springer Science+Business Media, LLC, part of Springer Nature. The large-scale polarization explorer (LSPE) is a cosmology program for the measurement of large-scale curl-like features (B-modes) in the polarization of the cosmic microwave background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by covering a large portion of the northern microwave sky. LSPE/STRIP is a coherent array of receivers planned to be operated from the Teide Observatory in Tenerife, for the control and characterization of the low-frequency polarized signals of galactic origin; LSPE/SWIPE is a balloon-borne bolometric polarimeter based on 330 large throughput multi-moded detectors, designed to measure the CMB polarization at 150 GHz and to monitor the polarized emission by galactic dust above 200 GHz. The combined performance and the expected level of systematics mitigation will allow LSPE to constrain primordial B-modes down to a tensor/scalar ratio of 10 - 2. We here report the status of the STRIP pre-commissioning phase and the progress in the characterization of the key subsystems of the SWIPE payload (namely the cryogenic polarization modulation unit and the multi-moded TES pixels) prior to receiver integration.

Permittivity and permeability of epoxy-magnetite powder composites at microwave frequencies

Journal of Applied Physics 127:4 (2020)

Authors:

M Zannoni, T Ghigna, Me Jones, A Simonetto

Abstract:

© 2020 Author(s). Radio, millimeter, and sub-millimeter astronomy experiments as well as remote sensing applications often require castable absorbers with well known electromagnetic properties to design and realize calibration targets. In this context, we fabricated and characterized two samples using different ratios of two easily commercially available materials: epoxy (Stycast 2850FT) and magnetite (F e 3 O 4) powder. We performed transmission and reflection measurements from 7 GHz up to 170 GHz with a vector network analyzer equipped with a series of standard horn antennas. Using an empirical model, we analyzed the data to extract complex permittivity and permeability from transmission data; then, we used reflection data to validate the results. In this paper, we present the sample fabrication procedure, analysis method, parameter extraction pipeline, and results for two samples with different epoxy-powder mass ratios.

Updated Design of the CMB Polarization Experiment Satellite LiteBIRD

JOURNAL OF LOW TEMPERATURE PHYSICS Springer Science and Business Media LLC 199:3-4 (2020) 1107-1117

Authors:

H Sugai, Par Ade, Y Akiba, D Alonso, K Arnold, J Aumont, J Austermann, C Baccigalupi, Aj Banday, R Banerji, Rb Barreiro, S Basak, J Beall, S Beckman, M Bersanelli, J Borrill, F Boulanger, Ml Brown, M Bucher, A Buzzelli, E Calabrese, Fj Casas, A Challinor, V Chan, Y Chinone, J-F Cliche, F Columbro, A Cukierman, D Curtis, P Danto, P de Bernardis, T de Haan, M De Petris, C Dickinson, M Dobbs, T Dotani, L Duband, A Ducout, S Duff, A Duivenvoorden, J-M Duval, K Ebisawa, T Elleflot, H Enokida, Hk Eriksen, J Errard, T Essinger-Hileman, F Finelli, R Flauger, C Franceschet

Abstract:

© 2020, The Author(s). Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite cosmic microwave background (CMB) polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA’s H3 rocket. It will accommodate more than 4000 TESs in focal planes of reflective low-frequency and refractive medium-and-high-frequency telescopes in order to detect a signature imprinted on the CMB by the primordial gravitational waves predicted in cosmic inflation. The total wide frequency coverage between 34 and 448 GHz enables us to extract such weak spiral polarization patterns through the precise subtraction of our Galaxy’s foreground emission by using spectral differences among CMB and foreground signals. Telescopes are cooled down to 5 K for suppressing thermal noise and contain polarization modulators with transmissive half-wave plates at individual apertures for separating sky polarization signals from artificial polarization and for mitigating from instrumental 1/f noise. Passive cooling by using V-grooves supports active cooling with mechanical coolers as well as adiabatic demagnetization refrigerators. Sky observations from the second Sun–Earth Lagrangian point, L2, are planned for 3 years. An international collaboration between Japan, the USA, Canada, and Europe is sharing various roles. In May 2019, the Institute of Space and Astronautical Science, JAXA, selected LiteBIRD as the strategic large mission No. 2.

The C-Band All-Sky Survey (C-BASS): Simulated parametric fitting in single pixels in total intensity and polarization

Monthly Notices of the Royal Astronomical Society Oxford University Press 490:2 (2019) 2958-2975

Authors:

Luke Jew, AC Taylor, Michael Jones, A Barr, HC Chiang, C Dickinson, RDP Grumitt, HM Heilgendorff, J Hill-Valler, JL Jonas, JP Leahy, J Leech, TJ Pearson, MW Peel, ACS Readhead, J Sievers

Abstract:

The cosmic microwave background (CMB) B-mode signal is potentially weaker than the diffuse Galactic foregrounds over most of the sky at any frequency. A common method of separating the CMB from these foregrounds is via pixel-based parametric-model fitting. There are not currently enough all-sky maps to fit anything more than the most simple models of the sky. By simulating the emission in seven representative pixels, we demonstrate that the inclusion of a 5 GHz data point allows for more complex models of low-frequency foregrounds to be fitted than at present. It is shown that the inclusion of the C-BASS data will significantly reduce the uncertainties in a number of key parameters in the modelling of both the galactic foregrounds and the CMB. The extra data allow estimates of the synchrotron spectral index to be constrained much more strongly than is presently possible, with corresponding improvements in the accuracy of the recovery of the CMB amplitude. However, we show that to place good limits on models of the synchrotron spectral curvature will require additional low-frequency data.

Gain stabilization for radio intensity mapping using a continuous-wave reference signal

Monthly Notices of the Royal Astronomical Society Oxford University Press 489:1 (2019) 548-554

Authors:

Alexander Pollak, CM Holler, ME Jones, AC Taylor

Abstract:

Stabilizing the gain of a radio astronomy receiver is of great importance for sensitive radio intensity mapping. In this paper we discuss a stabilization method using a continuous-wave reference signal injected into the signal chain and tracked in a single channel of the spectrometer to correct for the gain variations of the receiver. This method depends on the fact that gain fluctuations of the receiver are strongly correlated across the frequency band, which we can show is the case for our experimental set-up. This method is especially suited for receivers with a digital back-end with high spectral resolution and moderate dynamic range. The sensitivity of the receiver is unaltered except for one lost frequency channel. We present experimental results using a new 4–8.5 GHz receiver with a digital back-end that shows substantial reduction of the 1/f noise and the 1/f knee frequency.