A high power fibre laser for electron beam emittance measurements
Proceedings of IPAC 10 3227-3229
Abstract:
We present the latest results on the development of a high power fibre laser system for a laser-wire measuring electron beam emittance in an ILC-specification environment. The laser consists of a commercial Ytterbium (Yb) doped fibre laser system producing 1μJ pulses at 6.49MHz, which can be locked to an external frequency reference. This output has been amplified in a single 70cm rod type photonic crystal fibre (PCF), producing ~ 100μJ pulses in a burst mode at 2Hz (limited by diagnostics).Development of a high power fibre laser for laser based electron beam diagnostics
Proceedings of EPAC 08 1359-1361
Abstract:
L. Corner, Nicolas. Delerue, M. Newman, R. Walczak, Grahame A. Blair, S.T. Boogert, D.F. Howell and L.J. Nevay, ‘Development of a high power fibre laser for laser based electron beam diagnostics’, TUPC 124, EPAC 08.Guiding of high-intensity laser pulses in 100mm-long hydrodynamic optical-field-ionized plasma channels
Phys. Rev. Accel. Beams 23 081303-081303
Abstract:
Hydrodynamic optically-field-ionized (HOFI) plasma channels up to 100mm long are investigated. Optical guiding is demonstrated of laser pulses with a peak input intensity of $6\times10^{17}$ W cm$^{-2}$ through 100mm long plasma channels with on-axis densities measured interferometrically to be as low as $n_{e0} = (1.0\pm0.3)\times10^{17}$cm$^{-3}$. Guiding is also observed at lower axial densities, which are inferred from magneto-hydrodynamic simulations to be approximately $7\times10^{16}$cm$^{-3}$. Measurements of the power attenuation lengths of the channels are shown to be in good agreement with those calculated from the measured transverse electron density profiles. To our knowledge, the plasma channels investigated in this work are the longest, and have the lowest on-axis density, of any free-standing waveguide demonstrated to guide laser pulses with intensities above $>10^{17}$ W cm$^{-2}$.Micron size laser-wire system at the ATF extraction line
Proceedings of EPAC 08 1065-1067
Abstract:
The ATF extraction line laser-wire system has recently been upgraded allowing the measurement of micron scale transverse size electron beams. We report on the hardware upgrades, including focusing lens, laser and mechanical systems. First measurements using the new system from recent operation at the ATF in KEK are presented.Micron-scale Laser-wire at the ATF-II at KEK Commissioning and Results
Proceedings of IPAC 11 1401-1403