Skip to main content
Home
Department Of Physics text logo
  • Research
    • Our research
    • Our research groups
    • Our research in action
    • Research funding support
    • Summer internships for undergraduates
  • Study
    • Undergraduates
    • Postgraduates
  • Engage
    • For young people
    • For teachers
    • For the public
    • For alumni
    • For business
  • Support
Menu
Insertion of STC into TRT at the Department of Physics, Oxford
Credit: CERN

Philip Burrows

Professor of Physics

Sub department

  • Particle Physics
Philip.Burrows@physics.ox.ac.uk
Telephone: 01865 (2)73451
Denys Wilkinson Building, room 615a
  • About
  • Publications

Analysis of proton bunch parameters in the AWAKE experiment

Journal of Instrumentation IOP Publishing 16 (2021) P11031

Abstract:

A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along the beamline using scintillating or optical transition radiation screens. The parameters of a model that describes the bunch transverse dimensions and divergence are fitted to represent the observed data using Bayesian inference. The analysis is tested on simulated data and then applied to the experimental data.
More details from the publisher
Details from ORA
More details

Beam position detection of a short electron bunch in presence of a longer and more intense proton bunch for the AWAKE Experiment

JACoW Publishing, Geneva, Switzerland (2021) 75-79

Authors:

Philip Burrows, C Pakuza

Abstract:

The AWAKE experiment studies the acceleration of electrons to multi-GeV levels driven by the plasma wakefield generated by an ultra-relativistic and high intensity proton bunch. The proton beam, being considerably more intense than the co-propagating electron bunch, perturbs the measurement of the electron beam position achieved via standard techniques. This contribution shows that the electrons position monitoring is possible by frequency discrimination, exploiting the large bunch length difference between the electron and proton beams. Simulations and a beam measurement hint, the measurement has to be carried out in a frequency regime of a few tens of GHz, which is far beyond the spectrum produced by the 1ns long (4 σ Gaussian) proton bunch. As operating a conventional Beam Position Monitor (BPM) in this frequency range is problematic, an innovative approach based on the emission of coherent Cherenkov Diffraction Radiation (ChDR) in dielectrics is being studied. After describing the monitor concept and design, we will report about the results achieved with a prototype system at the CERN electron facility CLEAR.
More details from the publisher
Details from ORA

Updating the SiD Detector concept

(2021)

Authors:

M Breidenbach, Je Brau, P Burrows, T Markiewicz, M Stanitzki, J Strube, Ap White
Details from ORA
More details from the publisher
Details from ArXiV

High-resolution, low-latency, bunch-by-bunch feedback systems for nanobeam production and stabilization

JACoW Publishing, Geneva, Switzerland (2021) 458-465

Abstract:

High-precision intra-bunch-train beam orbit feedback correction systems have been developed and tested in the ATF2 beamline of the Accelerator Test Facility at the High Energy Accelerator Research Organization in Japan. Two systems are presented: 1) The vertical position of the bunch measured at two beam stripline position monitors (BPMs) is used to calculate a pair of kicks which are applied to the next bunch using two upstream kickers, thereby correcting both the vertical position and trajectory angle. This system was optimized so as to stabilize the beam offset at the feedback BPMs to better than 350 nm, yielding a local trajectory angle correction to within 250 nrad. Measurements with a beam size monitor at the focal point (IP) demonstrate that reducing the trajectory jitter of the beam by a factor of 4 also reduces the observed wakefield-induced increase in the measured beam size as a function of beam charge by a factor of c. 1.6. 2) High-resolution cavity BPMs were used to provide local beam stabilization in the IP region. The BPMs were demonstrated to achieve an operational resolution of ~20 nm. With the application of single-BPM and two-BPM feedback, beam stabilization of below 50 nm and 41 nm respectively has been achieved with a closed-loop latency of 232 ns.
More details from the publisher
Details from ORA

Methods for extremely sparse-angle proton tomography

PHYSICAL REVIEW E American Physical Society (APS) 104:4 (2021) 45201

Authors:

Bt Spiers, R Aboushelbaya, Q Feng, Mw Mayr, I Ouatu, Rw Paddock, R Timmis, Rh-W Wang, Pa Norreys

Abstract:

Proton radiography is a widely fielded diagnostic used to measure magnetic structures in plasma. The deflection of protons with multi-MeV kinetic energy by the magnetic fields is used to infer their path-integrated field strength. Here the use of tomographic methods is proposed for the first time to lift the degeneracy inherent in these path-integrated measurements, allowing full reconstruction of spatially resolved magnetic field structures in three dimensions. Two techniques are proposed which improve the performance of tomographic reconstruction algorithms in cases with severely limited numbers of available probe beams, as is the case in laser-plasma interaction experiments where the probes are created by short, high-power laser pulse irradiation of secondary foil targets. A new configuration allowing production of more proton beams from a single short laser pulse is also presented and proposed for use in tandem with these analytical advancements.
More details from the publisher
More details

Pagination

  • First page First
  • Previous page Prev
  • …
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Current page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • …
  • Next page Next
  • Last page Last

Footer Menu

  • Contact us
  • Giving to the Dept of Physics
  • Work with us
  • Media

User account menu

  • Log in

Follow us

FIND US

Clarendon Laboratory,

Parks Road,

Oxford,

OX1 3PU

CONTACT US

Tel: +44(0)1865272200

University of Oxfrod logo Department Of Physics text logo
IOP Juno Champion logo Athena Swan Silver Award logo

© University of Oxford - Department of Physics

Cookies | Privacy policy | Accessibility statement

Built by: Versantus

  • Home
  • Research
  • Study
  • Engage
  • Our people
  • News & Comment
  • Events
  • Our facilities & services
  • About us
  • Giving to Physics
  • Current students
  • Staff intranet