Superconducting phase transition thermometers for X-ray spectroscopy
PHYSICA B 284 (2000) 1998-1999
Abstract:
We report on a first attempt on a cryogenic imaging spectrometer based on sapphire absorber and two superconducting phase transition thermometers. One-dimensional imaging was achieved over a length of 10 mm with a spatial resolution of approximate to 200 mu m and an energy resolution of 216 eV for 5.89 keV X-rays. (C) 2000 Elsevier Science B.V. All rights reserved.The CRESST dark matter search
NUCL PHYS B-PROC SUP 87 (2000) 70-73
Abstract:
We present the current status of CRESST (Cryogenic Rare Event Search using Superconducting Thermometers) project and new results concerning detector development. The basic technique involved is to search for WIMPs by the measurement of non-thermal phonons, as created by WIMP-induced nuclear recoils. Combined with our newly developed method for the simultaneous measurement of scintillation light, strong background discrimination is possible, resulting in a substantial increase in WIMP detection sensitivity.Imaging X-ray spectroscopy with superconducting phase transition thermometers
NUCL INSTRUM METH A 444:1-2 (2000) 208-210
Abstract:
We report on the development of an imaging cryogenic X-ray spectrometer based upon X-ray absorption in sapphire and readout by two tungsten superconducting phase transition thermometers (SPTs). We achieve one-dimensional imaging over an absorber length of 10 mm with a position resolution of approximate to 200 mu m. (C) 2000 Elsevier Science B.V. All rights reserved.Quasiparticle diffusion and edge losses in superconducting tunnel junction detectors with two active electrodes
NUCL INSTRUM METH A 444:1-2 (2000) 15-18
Abstract:
A theoretical model to describe the spectral response of SIS tunnel junctions under irradiation in the presence of diffusion and edge losses of non-equilibrium quasiparticles has been developed. The model takes into account the back-tunnelling effect, in the general case of asymmetrical rates of tunnelling, gamma(12) not equal gamma(21). It provides a quantitative estimate of parameters like the edge reflectivity, the diffusion length and the diffusion coefficient, which are important parameters for a diagnostic of STJ-detectors. The predictions of the theory are compared with an experimental spectrum obtained from a Nb-based STJ. (C) 2000 Elsevier Science B.V. All rights reserved.Research of superconducting tunnel junction X-ray detectors with direct signal observation method using a fast current readout system
NUCL INSTRUM METH A 444:1-2 (2000) 124-128