Cryogenic detectors and their application to mass spectrometry

International Journal of Mass Spectrometry 215:1-3 (2002) 45-58

Abstract:

Cryogenic detectors are detectors based upon detection mechanisms which require low temperatures in the sub-kelvin range, such as superconductivity. This article introduces the two main representatives of cryogenic detectors, superconducting tunnel junctions and low-temperature calorimeters with superconducting thermometers. The operating principles, signal generation and noise sources are discussed in each case. These detectors are already applied to experiments in particle-astrophysics and in optical astronomy. They are considered as the next generation instrumentation in certain areas of astrophysics, material analysis and high-resolution spectroscopy. Since 1996, they are also considered for applications in time-of-flight spectrometry of heavy bio-molecules. Successful applications of both detectors types in this area are briefly reviewed. © 2002 Elsevier Science B.V. All rights reserved.

Results of CRESST phase I

AIP Conference Proceedings AIP Publishing 605:1 (2002) 481-484

Authors:

C Cozzini, M Altmann, G Angloher, M Bruckmayer, C Bucci, S Cooper, P Di Stefano, F von Feilitzsch, T Frank, D Hauff, Th Jagemann, J Jochum, R Keeling, H Kraus, J Macallister, F Pröbst, Y Ramachers, J Schnagl, W Seidel, I Sergeyev, M Stark, L Stodolsky, H Wulandari

Development of mm(2)-size high energy resolution X-ray detectors using W-SPT

AIP CONF PROC 605 (2002) 227-230

Authors:

G Angloher, A Bento, H Kraus, F Probst, W Seidel

Abstract:

The low transition temperature of tungsten should allow fabrication of X-ray detectors combining high-energy resolution and enlarged absorber area (similar to1 mm(2)). We present first results obtained for lead and gold absorbers read out by tungsten superconducting phase transition thermometers (W-SPT) using a variety of detector geometries.

The 66-channel SQUID readout system for CRESST II

AIP CONF PROC 605 (2002) 333-336

Authors:

H Kraus, N Bazin, S Cooper, S Henry

Abstract:

The upgrade of the CRESST experiment to a 10 kg target of phonon/light detectors necessitates the installation of 66 readout channels in the CRESST cryostat. We report on the status of this upgrade and discuss the issues related to the installation of the correspondingly high number of SQUIDs and wires in an ultra-low temperature environment.

The CRESST Dark Matter Search Status and Future

Chapter in Dark Matter in Astro- and Particle Physics, Springer Nature (2002) 517-523

Authors:

Wolfgang Seidel, M Altmann, G Angloher, C Bucci, S Cooper, C Cozzini, F von Feilitzsch, T Frank, D Hauff, Th Jagemann, J Jochum, R Keeling, H Kraus, J Macallister, F Pröbst, Y Ramachers, A Rulofs, M Stark, L Stodolsky, S Uchaikin, H Wulandari