Combined performance studies for electrons at the 2004 ATLAS combined test-beam
Journal of Instrumentation 5:11 (2010)
Abstract:
In 2004 at the ATLAS (A Toroidal LHC ApparatuS) combined test beam, one slice of the ATLAS barrel detector (including an Inner Detector set-up and the Liquid Argon calorimeter) was exposed to particles from the H8 SPS beam line at CERN. It was the first occasion to test the combined electron performance of ATLAS. This paper presents results obtained for the momentum measurement p with the Inner Detector and for the performance of the electron measurement with the LAr calorimeter (energy E linearity and resolution) in the presence of a magnetic field in the Inner Detector for momenta ranging from 20 GeV/c to 100 GeV/c. Furthermore the particle identification capabilities of the Transition Radiation Tracker, Bremsstrahlungs-recovery algorithms relying on the LAr calorimeter and results obtained for the E/p ratio and a way how to extract scale parameters will be discussed. © 2010 IOP Publishing Ltd and SISSA.The radiation hardness of specific multi-mode and single-mode optical fibres at -25°C beyond a full SLHC dose to a dose of 500 kGy(Si)
Journal of Instrumentation 5:11 (2010)
Abstract:
The optical fibres that will be used in SLHC detectors will be exposed to high doses and low temperatures in the inner detectors. A number of single-Mode (sM) and Multi-Mode (MM) fibres have been tested for radiation hardness by exposure beyond a full SLHC dose to 500 kGy(Si) in the -25 °C operating temperatures expected in the upgraded inner detectors. From these measurements conservative estimates of the level of Radiation Induced Absorption (RIA) have been calculated for these fibres in realistic paths through an upgraded inner detector. Two SM fibres have been found whose total calculated RIAs were much lower than the budgeted 1 dB, despite the high dose rates used in the experiment. The RIAs for the DrakaElite Super RadHard Single-Mode Fiber and Fibre X were calculated to be 0.142 and 0.064 dB respectively. Another SM and a MM fibre showed high levels of RIA during the experiment, however they cannot be ruled out as candidate fibres due the the high dose rate of 27 kGy(Si)/hr used. © 2010 IOP Publishing Ltd and SISSA.Inclusive dijet cross sections in neutral current deep inelastic scattering at HERA
ArXiv 1010.6167 (2010)
Feasibility study of PbWO4 and PbMoO4 crystal scintillators for cryogenic rare events experiments
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 622:3 (2010) 608-613
Abstract:
Scintillation properties of PbWOMeasurement of the W -> lnu and Z/gamma* -> ll production cross sections in proton-proton collisions at sqrt(s) = 7 TeV with the ATLAS detector
ArXiv 1010.213 (2010)