Novel X-band transverse deflection structure with variable polarization

Physical Review Accelerators and Beams American Physical Society (APS) 23:11 (2020) 112001

Authors:

P Craievich, M Bopp, H-H Braun, A Citterio, R Fortunati, R Ganter, T Kleeb, F Marcellini, M Pedrozzi, E Prat, S Reiche, K Rolli, R Sieber, A Grudiev, WL Millar, N Catalan-Lasheras, G McMonagle, S Pitman, V del Pozo Romano, KT Szypula, W Wuensch, B Marchetti, R Assmann, F Christie, B Conrad, R D’Arcy, M Foese, P Gonzalez Caminal, M Hoffmann, M Huening, R Jonas, O Krebs, S Lederer, D Marx, J Osterhoff, M Reukauff, H Schlarb, S Schreiber, G Tews, M Vogt, A de Z. Wagner, S Wesch

High-resolution sampling of beam-driven plasma wakefields.

Nature communications 11:1 (2020) 5984

Authors:

S Schröder, CA Lindstrøm, S Bohlen, G Boyle, R D'Arcy, S Diederichs, MJ Garland, P Gonzalez, A Knetsch, V Libov, P Niknejadi, Kris Põder, L Schaper, B Schmidt, B Sheeran, G Tauscher, S Wesch, J Zemella, M Zeng, J Osterhoff

Abstract:

Plasma-wakefield accelerators driven by intense particle beams promise to significantly reduce the size of future high-energy facilities. Such applications require particle beams with a well-controlled energy spectrum, which necessitates detailed tailoring of the plasma wakefield. Precise measurements of the effective wakefield structure are therefore essential for optimising the acceleration process. Here we propose and demonstrate such a measurement technique that enables femtosecond-level (15 fs) sampling of longitudinal electric fields of order gigavolts-per-meter (0.8 GV m-1). This method-based on energy collimation of the incoming bunch-made it possible to investigate the effect of beam and plasma parameters on the beam-loaded longitudinally integrated plasma wakefield, showing good agreement with particle-in-cell simulations. These results open the door to high-quality operation of future plasma accelerators through precise control of the acceleration process.

Guiding of high-intensity laser pulses in 100mm-long hydrodynamic optical-field-ionized plasma channels

Physical Review Accelerators and Beams American Physical Society 23:8 (2020) 081303

Authors:

A Picksley, A Alejo, J Cowley, N Bourgeois, L Corner, L Feder, J Holloway, H Jones, J Jonnerby, Hm Milchberg, Lr Reid, Aj Ross, R Walczak, Sm Hooker

Abstract:

Hydrodynamic optically-field-ionized (HOFI) plasma channels up to 100mm long are investigated. Optical guiding is demonstrated of laser pulses with a peak input intensity of $6\times10^{17}$ W cm$^{-2}$ through 100mm long plasma channels with on-axis densities measured interferometrically to be as low as $n_{e0} =(1.0\pm0.3)\times10^{17}$cm$^{-3}$. Guiding is also observed at lower axial densities, which are inferred from magneto-hydrodynamic simulations to be approximately $7\times10^{16}$cm$^{-3}$. Measurements of the power attenuation lengths of the channels are shown to be in good agreement with those calculated from the measured transverse electron density profiles. To our knowledge, the plasma channels investigated in this work are the longest, and have the lowest on-axis density, of any free-standing waveguide demonstrated to guide laser pulses with intensities above $>10^{17}$ W cm$^{-2}$.

Numerical modelling of chromatic effects on axicon-focused beams used to generate HOFI plasma channels

Journal of Physics: Conference Series IOP Publishing 1596 (2020)

Authors:

Aimee Ross, Aaron Alejo, Alexander von Boetticher, James Cowley, James Holloway, Jakob Jonnerby, Alexander Picksley, Roman Walczak, Simon Hooker

Abstract:

Hydrodynamic optical-field-ionised (HOFI) plasma channels promise a route towards high repetition-rate, metre-scale stages for future laser plasma accelerators. These channels are formed by hydrodynamic expansion of a plasma column produced by optical field ionisation at the focus of a laser, typically from an axicon lens. Since the laser pulses used to generate the initial plasma column are of sub-picosecond duration, chromatic effects in the axicon lens could be important. In this paper we assess these effects using a numerical propagation code. The code is validated using analytical formulae and experimental data. For the parameter range investigated, dispersive effects are found to be of minor importance, reducing the peak on-axis intensity in the focal region by approximately 10%.

Summary of Working Group 5: Plasma devices, plasma and beam diagnostics

Journal of Physics Conference Series IOP Publishing 1596:1 (2020) 012042

Authors:

Richard D’Arcy, Nicolas Delerue