FLASHForward X-2: Towards beam quality preservation in a plasma booster

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment Elsevier 909 (2018) 80-83

Authors:

V Libov, A Aschikhin, J Dale, R D’Arcy, K Ludwig, A Martinez de la Ossa, T Mehrling, J-H Roeckemann, L Schaper, B Schmidt, S Schröder, S Wesch, J Zemella, J Osterhoff

Calibration and cross-laboratory implementation of scintillating screens for electron bunch charge determination.

The Review of scientific instruments 89:9 (2018) 093303

Authors:

Thomas Kurz, Jurjen Pieter Couperus, Jakob Matthias Krämer, Hao Ding, Stephan Kuschel, Alexander Köhler, Omid Zarini, Dominik Hollatz, David Schinkel, Richard D'Arcy, Jan-Patrick Schwinkendorf, Jens Osterhoff, Arie Irman, Ulrich Schramm, Stefan Karsch

Abstract:

We revise the calibration of scintillating screens commonly used to detect relativistic electron beams with low average current, e.g., from laser-plasma accelerators, based on new and expanded measurements that include higher charge density and different types of screens than previous work [Buck et al., Rev. Sci. Instrum. 81, 033301 (2010)]. Electron peak charge densities up to 10 nC/mm2 were provided by focused picosecond-long electron beams delivered by the Electron Linac for beams with high Brilliance and low Emittance (ELBE) at the Helmholtz-Zentrum Dresden-Rossendorf. At low charge densities, a linear scintillation response was found, followed by the onset of saturation in the range of nC/mm2. The absolute calibration factor (photons/sr/pC) in this linear regime was measured to be almost a factor of 2 lower than that reported by Buck et al. retrospectively implying a higher charge in the charge measurements performed with the former calibration. A good agreement was found with the results provided by Glinec et al. [Rev. Sci. Instrum. 77, 103301 (2006)]. Furthermore long-term irradiation tests with an integrated dose of approximately 50 nC/mm2 indicate a significant decrease of the scintillation efficiency over time. Finally, in order to enable the transfer of the absolute calibration between laboratories, a new constant reference light source has been developed.

Simulations of 3D charge density measurements for commissioning of the PolariX-TDS

Journal of Physics Conference Series IOP Publishing 1067 (2018) 072012

Authors:

D Marx, R Assmann, R D’Arcy, B Marchetti

Status of the Transverse Diagnostics at FLASHForward

Journal of Physics Conference Series IOP Publishing 1067 (2018) 042010

Authors:

P Niknejadi, R D’Arcy, MC Kaluza, A Knetsch, V Libov, A Martinez de la Ossa, TJ Mehrling, J Osterhoff, CAJ Palmer, K Poder, A Sävert, L Schaper, MB Schwab, C Wirth

PIP-II injector test’s low energy beam transport: Commissioning and selected measurements

AIP Conference Proceedings AIP Publishing 1869:1 (2017) 050003

Authors:

A Shemyakin, M Alvarez, R Andrews, J-P Carneiro, A Chen, R D’Arcy, B Hanna, L Prost, V Scarpine, C Wiesner