Performance of the CMS drift-tube chamber local trigger with cosmic rays

Journal of Instrumentation 5:3 (2010)

Authors:

S Chatrchyan, V Khachatryan, AM Sirunyan, W Adam, B Arnold, H Bergauer, T Bergauer, M Dragicevic, M Eichberger, J Erö, M Friedl, R Frühwirth, VM Ghete, J Hammer, S Hansel, M Hoch, N Hörmann, J Hrubec, M Jeitler, G Kasieczka, K Kastner, M Krammer, D Liko, I De Magrans Abril, I Mikulec, F Mittermayr, B Neuherz, M Oberegger, M Padrta, M Pernicka, H Rohringer, S Schmid, R Schöfbeck, T Schreiner, R Stark, H Steininger, J Strauss, A Taurok, F Teischinger, T Themel, D Uhl, P Wagner, W Waltenberger, G Walzel, E Widl, CE Wulz, V Chekhovsky, O Dvornikov, I Emeliantchik, A Litomin, V Makarenko, I Marfin, V Mossolov, N Shumeiko, A Solin, R Stefanovitch, J Suarez Gonzalez, A Tikhonov, A Fedorov, A Karneyeu, M Korzhik, V Panov, R Zuyeuski, P Kuchinsky, W Beaumont, L Benucci, M Cardaci, EA De Wolf, E Delmeire, D Druzhkin, M Hashemi, X Janssen, T Maes, L Mucibello, S Ochesanu, R Rougny, M Selvaggi, H Van Haevermaet, P Van Mechelen, N Van Remortel, V Adler, S Beauceron, S Blyweert, J D'Hondt, S De Weirdt, O Devroede, J Heyninck, A Kalogeropoulos, J Maes, M Maes, MU Mozer, S Tavernier, W Van Doninck, P Van Mulders, I Villella, O Bouhali, EC Chabert, O Charaf, B Clerbaux, G De Lentdecker

Abstract:

The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams. © 2010 IOP Publishing Ltd and SISSA.

Performance study of the CMS barrel resistive plate chambers with cosmic rays

Journal of Instrumentation 5:3 (2010)

Authors:

S Chatrchyan, V Khachatryan, AM Sirunyan, W Adam, B Arnold, H Bergauer, T Bergauer, M Dragicevic, M Eichberger, J Erö, M Friedl, R Frühwirth, VM Ghete, J Hammer, S Hansel, M Hoch, N Hörmann, J Hrubec, M Jeitler, G Kasieczka, K Kastner, M Krammer, D Liko, I De Magrans Abril, I Mikulec, F Mittermayr, B Neuherz, M Oberegger, M Padrta, M Pernicka, H Rohringer, S Schmid, R Schöfbeck, T Schreiner, R Stark, H Steininger, J Strauss, A Taurok, F Teischinger, T Themel, D Uhl, P Wagner, W Waltenberger, G Walzel, E Widl, CE Wulz, V Chekhovsky, O Dvornikov, I Emeliantchik, A Litomin, V Makarenko, I Marfin, V Mossolov, N Shumeiko, A Solin, R Stefanovitch, J Suarez Gonzalez, A Tikhonov, A Fedorov, A Karneyeu, M Korzhik, V Panov, R Zuyeuski, P Kuchinsky, W Beaumont, L Benucci, M Cardaci, EA De Wolf, E Delmeire, D Druzhkin, M Hashemi, X Janssen, T Maes, L Mucibello, S Ochesanu, R Rougny, M Selvaggi, H Van Haevermaet, P Van Mechelen, N Van Remortel, V Adler, S Beauceron, S Blyweert, J D'Hondt, S De Weirdt, O Devroede, J Heyninck, A Kalogeropoulos, J Maes, M Maes, MU Mozer, S Tavernier, W Van Doninck, P Van Mulders, I Villella, O Bouhali, EC Chabert, O Charaf, B Clerbaux, G De Lentdecker

Abstract:

In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported. © 2010 IOP Publishing Ltd and SISSA.

Precise mapping of the magnetic field in the CMS barrel yoke using cosmic rays

Journal of Instrumentation 5:3 (2010)

Authors:

S Chatrchyan, V Khachatryan, AM Sirunyan, W Adam, B Arnold, H Bergauer, T Bergauer, M Dragicevic, M Eichberger, J Erö, M Friedl, R Frühwirth, VM Ghete, J Hammer, S Hansel, M Hoch, N Hörmann, J Hrubec, M Jeitler, G Kasieczka, K Kastner, M Krammer, D Liko, I De Magrans Abril, I Mikulec, F Mittermayr, B Neuherz, M Oberegger, M Padrta, M Pernicka, H Rohringer, S Schmid, R Schöfbeck, T Schreiner, R Stark, H Steininger, J Strauss, A Taurok, F Teischinger, T Themel, D Uhl, P Wagner, W Waltenberger, G Walzel, E Widl, CE Wulz, V Chekhovsky, O Dvornikov, I Emeliantchik, A Litomin, V Makarenko, I Marfin, V Mossolov, N Shumeiko, A Solin, R Stefanovitch, J Suarez Gonzalez, A Tikhonov, A Fedorov, A Karneyeu, M Korzhik, V Panov, R Zuyeuski, P Kuchinsky, W Beaumont, L Benucci, M Cardaci, EA De Wolf, E Delmeire, D Druzhkin, M Hashemi, X Janssen, T Maes, L Mucibello, S Ochesanu, R Rougny, M Selvaggi, H Van Haevermaet, P Van Mechelen, N Van Remortel, V Adler, S Beauceron, S Blyweert, J D'Hondt, S De Weirdt, O Devroede, J Heyninck, A Kalogeropoulos, J Maes, M Maes, MU Mozer, S Tavernier, W Van Doninck, P Van Mulders, I Villella, O Bouhali, EC Chabert, O Charaf, B Clerbaux, G De Lentdecker

Abstract:

The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12 000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location. © 2010 IOP Publishing Ltd and SISSA.

The goldstini variations

Journal of High Energy Physics 2010:10 (2010)

Authors:

N Craig, J March-Russell, M McCullough

Abstract:

We study the 'goldstini' scenario of Cheung, Nomura, and Thaler, in which multiple independent supersymmetry (SUSY) breaking sectors lead to multiple would-be goldstinos, changing collider and cosmological phenomenology. In supergravity, potentially large corrections to the previous prediction of twice the gravitino mass for goldstini masses can arise when their scalar partners are stabilized far from the origin. Considerations arising from the complexity of realistic string compactifications indicate that many of the independent SUSY-breaking sectors should be conformally sequestered or situated in warped Randall-Sundrum-like throats, further changing the predicted goldstini masses. If the sequestered hidden sector is a metastable SUSY-breaking sector of the Intriligator-Seiberg-Shih (ISS) type then multiple goldstini can originate from within a single sector, along with many supplementary 'modulini', all with masses of order twice the gravitino mass. These fields can couple to the Supersymmetric Standard Model (SSM) via the 'Goldstino Portal'. Collider signatures involving SSM sparticle decays can provide strong evidence for warped-or-conformally-sequestered sectors, and of the ISS mechanism of SUSY breaking. Along with axions and photini, the Goldstino Portal gives another potential window to the hidden sectors of string theory. © SISSA 2010.

Time reconstruction and performance of the CMS electromagnetic calorimeter

Journal of Instrumentation 5:3 (2010)

Authors:

S Chatrchyan, V Khachatryan, AM Sirunyan, W Adam, B Arnold, H Bergauer, T Bergauer, M Dragicevic, M Eichberger, J Erö, M Friedl, R Frühwirth, VM Ghete, J Hammer, S Hansel, M Hoch, N Hörmann, J Hrubec, M Jeitler, G Kasieczka, K Kastner, M Krammer, D Liko, I De Magrans Abril, I Mikulec, F Mittermayr, B Neuherz, M Oberegger, M Padrta, M Pernicka, H Rohringer, S Schmid, R Schöfbeck, T Schreiner, R Stark, H Steininger, J Strauss, A Taurok, F Teischinger, T Themel, D Uhl, P Wagner, W Waltenberger, G Walzel, E Widl, CE Wulz, V Chekhovsky, O Dvornikov, I Emeliantchik, A Litomin, V Makarenko, I Marfin, V Mossolov, N Shumeiko, A Solin, R Stefanovitch, J Suarez Gonzalez, A Tikhonov, A Fedorov, A Karneyeu, M Korzhik, V Panov, R Zuyeuski, P Kuchinsky, W Beaumont, L Benucci, M Cardaci, EA De Wolf, E Delmeire, D Druzhkin, M Hashemi, X Janssen, T Maes, L Mucibello, S Ochesanu, R Rougny, M Selvaggi, H Van Haevermaet, P Van Mechelen, N Van Remortel, V Adler, S Beauceron, S Blyweert, J D'Hondt, S De Weirdt, O Devroede, J Heyninck, A Kalogeropoulos, J Maes, M Maes, MU Mozer, S Tavernier, W Van Doninck, P Van Mulders, I Villella, O Bouhali, EC Chabert, O Charaf, B Clerbaux, G De Lentdecker

Abstract:

The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. © 2010 IOP Publishing Ltd and SISSA.