Measurement of the WW+WZ production cross section using a matrix element technique in lepton+jets events
Physical Review D - Particles, Fields, Gravitation and Cosmology 82:11 (2010)
Abstract:
We present a measurement of the WW+WZ production cross section observed in a final state consisting of an identified electron or muon, two jets, and missing transverse energy. The measurement is carried out in a data sample corresponding to up to 4.6fb⊃-1 of integrated luminosity at √s=1.96TeV collected by the CDF II detector. Matrix element calculations are used to separate the diboson signal from the large backgrounds. The WW+WZ cross section is measured to be 17.4±3.3pb in agreement with standard model predictions. A fit to the dijet invariant mass spectrum yields a compatible cross section measurement. © 2010 The American Physical Society.Measurement of the superconducting transition temperature of Dural and titanium 6Al–4V alloys
Superconductor Science and Technology IOP Publishing 23:12 (2010) 129801
Performance of the ATLAS detector using first collision data
Journal of High Energy Physics 2010:9 (2010)
Abstract:
More than half a million minimum-bias events of LHC collision data were collected by the ATLAS experiment in December 2009 at centre-of-mass energies of 0.9 TeV and 2.36 TeV. This paper reports on studies of the initial performance of the ATLAS detector from these data. Comparisons between data and Monte Carlo predictions are shown for distributions of several track-and calorimeter-based quantities. The good performance of the ATLAS detector in these first data gives confidence for successful running at higher energies.Readiness of the ATLAS Tile Calorimeter for LHC collisions
European Physical Journal C 70:4 (2010) 1193-1236
Abstract:
The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the detector has successfully collected data from the LHC single beams in 2008 and first collisions in 2009. This paper gives an overview of the Tile Calorimeter performance as measured using random triggers, calibration data, data from cosmic ray muons and single beam data. The detector operation status, noise characteristics and performance of the calibration systems are presented, as well as the validation of the timing and energy calibration carried out with minimum ionising cosmic ray muons data. The calibration systems' precision is well below the design value of 1%. The determination of the global energy scale was performed with an uncertainty of 4%. © 2010 CERN for the benefit of the ATLAS collaboration.Readiness of the ATLAS liquid argon calorimeter for LHC collisions
European Physical Journal C 70:3 (2010) 723-753