Revealing a high water abundance in the upper mesosphere of Mars with ACS onboard TGO
Geophysical Research Letters Wiley 48:10 (2021) e2021GL093411
Abstract:
We present the first water vapor profiles encompassing the upper mesosphere of Mars, 100–120 km, far exceeding the maximum altitudes where remote sensing has been able to observe water to date. Our results are based on solar occultation measurements by Atmospheric Chemistry Suite (ACS) onboard the ExoMars Trace Gas Orbiter (TGO). The observed wavelength range around 2.7 μm possesses strong CO2 and H2O absorption lines allowing sensitive temperature and density retrievals. We report a maximum H2O mixing ratio varying from 10 to 50 ppmv at 100–120 km during the global dust storm (GDS) of Martian Year (MY) 34 and around southern summer solstice of MY 34 and 35. During other seasons water remains persistently below ∼2 ppmv. We claim that contributions of the MY34 GDS and perihelion periods into the projected hydrogen escape from Mars are nearly equivalent.Longitudinal variations in the stratosphere of Uranus from the Spitzer infrared spectrometer
Icarus Elsevier 365 (2021) 114506
Abstract:
NASA's Spitzer Infrared Spectrometer (IRS) acquired mid-infrared (5–37 μm) disc-averaged spectra of Uranus very near to its equinox in December 2007. A mean spectrum was constructed from observations of multiple central meridian longitudes, spaced equally around the planet, which has provided the opportunity for the most comprehensive globally-averaged characterisation of Uranus' temperature and composition ever obtained (Orton et al., 2014a,b). In this work we analyse the disc-averaged spectra at four separate central meridian longitudes to reveal significant longitudinal variability in thermal emission occurring in Uranus' stratosphere during the 2007 equinox. We detect a variability of up to 15% at wavelengths sensitive to stratospheric methane, ethane and acetylene at the ~0.1-mbar level. The tropospheric hydrogen‑helium continuum and deuterated methane absorption exhibit a negligible variation (less than 2%), constraining the phenomenon to the stratosphere. Building on the forward-modelling analysis of the global average study, we present full optimal estimation inversions (using the NEMESIS retrieval algorithm, Irwin et al., 2008) of the Uranus-2007 spectra at each longitude to distinguish between thermal and compositional variability. We found that the variations can be explained by a temperature change of less than 3 K in the stratosphere. Near-infrared observations from Keck II NIRC2 in December 2007 (Sromovsky et al., 2009; de Pater et al., 2011), and mid-infrared observations from VLT/VISIR in 2009 (Roman et al., 2020), help to localise the potential sources to either large scale uplift or stratospheric wave phenomena.Investigation of Venus Cloud Aerosol and Gas Composition Including Potential Biogenic Materials via an Aerosol-Sampling Instrument Package.
Astrobiology (2021)
Abstract:
A lightweight, low-power instrument package to measure, <i>in situ,</i> both (1) the local gaseous environment and (2) the composition and microphysical properties of attendant venusian aerosols is presented. This Aerosol-Sampling Instrument Package (ASIP) would be used to explore cloud chemical and possibly biotic processes on future aerial missions such as multiweek balloon missions and on short-duration (<1 h) probes on Venus and potentially on other cloudy worlds such as Titan, the Ice Giants, and Saturn. A quadrupole ion-trap mass spectrometer (QITMS; Madzunkov and Nikolić, <i>J Am Soc Mass Spectrom</i> 25:1841-1852, 2014) fed alternately by (1) an aerosol separator that injects only aerosols into a vaporizer and mass spectrometer and (2) the pure aerosol-filtered atmosphere, achieves the compositional measurements. Aerosols vaporized <600°C are measured over atomic mass ranges from 2 to 300 AMU at <0.02 AMU resolution, sufficient to measure trace materials, their isotopic ratios, and potential biogenic materials embedded within H<sub>2</sub>SO<sub>4</sub> aerosols, to better than 20% in <300 s for H<sub>2</sub>SO<sub>4</sub> -relative abundances of 2 × 10<sup>-9</sup>. An integrated lightweight, compact nephelometer/particle-counter determines the number density and particle sizes of the sampled aerosols.Upper limits for phosphine (PH3) in the atmosphere of Mars
Astronomy and Astrophysics EDP Sciences 649:May 2021 (2021) L1
Abstract:
Phosphine (PH3) is proposed to be a possible biomarker in planetary atmospheres and has been claimed to have been observed in the atmosphere of Venus, sparking interest in the habitability of Venus’s atmosphere. Observations of another biomarker, methane (CH4), have been reported several times in the atmosphere of Mars, hinting at the possibility of a past or present biosphere. The Atmospheric Chemistry Suite on the ExoMars Trace Gas Orbiter has a spectral range that includes several absorption lines of PH3 with line strengths comparable to previously observed CH4 lines. The signature of PH3 was not observed in the 192 observations made over a full Martian year of observations, and here we report upper limits of 0.1–0.6 ppbv.Observations of Mars with ALMA: potential for future constraints of global circulation models
JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS 7:2 (2021) ARTN 025001